KitchenAid and Whirlpool Gas and Electric Ranges Error codes and causes
F0 E0
Default No Errors
F1 E0
F1 E0
User Interface (UI) Board Replace UI
F1 E1
F1 E1
User Interface (UI) Board Replace UI
F2 E0
F2 E0
Keypad Disconnected Check connections If necessary replace Keypad
F2 E1
F2 E1
Stuck Key/ Shorted Key Replace Keypad
F2 E2
F2 E2
Display/LED error Replace Display Board/LED
F3 E0
F3 E0
Main Oven Temperature Sensor Check for 1000‐1200Ω
F3 E1
F3 E1
Lower Oven Temperature Sensor Check for 1000‐1200Ω
F3 E2
F3 E2
Warming Drawer Temperature Sensor Check temp readout in Diagnostic Mode
F3 E4
F3 E4
Meat Probe Sensor/Jack Shorted Check both components for failure
F5 E0
F5 E0
Door Position/Door Latch Switch Check Oven Light ON/OFF – Check Door Latch for continuity/open
F5 E1
F5 E1
Door Latch not Operating Check Latch Switch/Latch Motor
F6 E6
F6 E6
Main Oven AM ‐ Lost Communication Check Main Oven AM connections
F6 E8
F6 E8
Microwave Oven AM ‐ Lost Communication Check Microwave Oven AM connections
F6 E9
F6 E9
Lower Oven AM ‐ Lost Communication Check Lower Oven AM connections
F8 E1
F8 E1
Cooling Fan Speed to slow Check Speed of Blower via Diagnostic Mode
F8 E2
F8 E2
Cooling Fan Speed to fast Check Speed of Blower via Diagnostic Mode
F9 E0
F9 E0
Unit mis‐wired at house supply Check supply wiring
JennAir – KitchenAid - Maytag and Whirlpool Microwave Ovens Error codes and causes
F2
Keyboard/User Interface
Check Keyboard/User Interface connections ‐ If OK, Replace component(s)
F2 E1
F2 E1
Touch Panel/User Interface
Replace Touch Panel/UI
F3
F3
Cavity Temperature Sensor
Check Sensor connections, if good ‐ Replace Sensor. Problem persists‐replace Control Board.
F3C
F3C
Cavity Temperature Sensor
Check Sensor connections, if good ‐ Replace Sensor. Problem persists‐replace Control Board.
F3H
F3H
Humidity Sensor
Replace Humidity Sensor, plug MW in & wait 30‐40 seconds. Problem persists ‐ Replace Control Board.
F4 E4
F4 E4
Humidity Sensor
Replace Humidity Sensor, plug MW in & wait 90 seconds. Problem persists ‐ Replace Control Board.
F5
F5
Boiler Temperature Sensor
Check Sensor connections ‐ Check for 70K‐130KΩ resistance
F6
F6
Microwave Relay (4903) on Control Board
Check connections between Relay 4903 and Control Board. Replace Control Board
F8
F8
Display Board memory communication
Verify error‐Replace UI/Control Board
F9
F9
Relay control board communication error.
Check communication cable between relay and control board .if goog replace the relay board and relay control board
F13
F13
WIDE (Appliance Manager‐UI) communication
Verify error‐Check connections between AM and UI boards ‐ Good connections, replace AM. Problem persists ‐ Replace UI.
JennAir, KitchenAid, Maytag and Whirlpool Induction Cooktops Error codes and causes
There are 3 types of failures associated with the Cooktop. The description of these failures and the impact theywill have on the rest of the Cooktop are listed in the following.
Failure – Type 1
Failure type 1 comes from the power control board. This failure will affect only one burner. The user may continue to use the other burners.
Failure – Type 2
Failure type 2 usually comes from the power control board (there could be some exceptions). These failures affect all burners associated with that power control board; the user may continue to use the burners that belong to the other power control board.
Failure – Type 3
Failure type 3 comes from the User Interface. This failure disables the entire Cooktop. When this type of failure occurs, all the burners are switched Off by the User Interface.
Failure – Type 1
Failure type 1 comes from the power control board. This failure will affect only one burner. The user may continue to use the other burners.
Failure – Type 2
Failure type 2 usually comes from the power control board (there could be some exceptions). These failures affect all burners associated with that power control board; the user may continue to use the burners that belong to the other power control board.
Failure – Type 3
Failure type 3 comes from the User Interface. This failure disables the entire Cooktop. When this type of failure occurs, all the burners are switched Off by the User Interface.
F‐12
Coil under current Type 1
Check for 240 volts at connection T2A ‐ T2B or T3A ‐ T3B on thepowercontrol board (whichever connection the burner is plugged into). If voltage is not correct, disconnect power and replace the power control board.
F‐21
F‐21
Supply power frequency Type 2
Replace the power control board
F‐25
Replace the power control board
F‐25
Stuck fan on power control board Type 2
Check that the cooling fan connector is firmly plugged in. Problem persists‐Replace the cooling fan
F‐36, F37
F‐36, F37
Temperature sensor is not working Type 1
Check that the temperature sensoris 1000 Ω at roomtemperature and is firmly plugged in. Problem persists‐replace the non‐working coil and the control board.
F‐40
F‐40
Power control board failure Type 1 or Type 2
Check the cable between the User Interface and the power control board is good and properly connected. Problem persists‐Replace the power control board.
F‐42
Check the cable between the User Interface and the power control board is good and properly connected. Problem persists‐Replace the power control board.
F‐42
Power supply Type 2
Check for 240 volts AC at the mainincoming power supply and check for an open fuse on the EMI filter board. Problem persists‐Replace the power control board.
F‐47
Power supply from power control board to User Interface is missing or WIDE communication error.
Check the continuity between L1 on the terminal block and both L1 terminals on between UI and power control board or an open fuse on the filter board Type 2 the EMI filter board. If there is not continuity on one or both of these lines, replace the thermofuse harness. Check the continuity of the fuses on the EMI board. If either of the fuses is blown, replace with a new one. Problem persists‐Change both control boards.
Check the continuity between L1 on the terminal block and both L1 terminals on between UI and power control board or an open fuse on the filter board Type 2 the EMI filter board. If there is not continuity on one or both of these lines, replace the thermofuse harness. Check the continuity of the fuses on the EMI board. If either of the fuses is blown, replace with a new one. Problem persists‐Change both control boards.
F‐56
Wrong or invalid UI configuration. Type 3
Reconfigure the cooktop following the directions in “Manual Configuration Mode.” Problem persists‐ Replace the User Interface.
F‐58
Wrong or invalid power control boardconfiguration Type 2
Reconfigure the Cooktop following the directions in “Manual Configuration Mode.” Problem persists‐Replace the power control board.
Reconfigure the Cooktop following the directions in “Manual Configuration Mode.” Problem persists‐Replace the power control board.
F‐61
Power control board does not work
Check that the cables between the UserInterface and the power control board are not damaged and are firmly plugged in. Check for 240 Volts AC at the J1 connector on the power control board. Reconnect power and confirm voltage reading. If voltage is not correct, disconnect power and have a qualified electrician check the home power supply. Problem persists‐Replace the cable between the User Interface and the power control board.